Only two named systems
The category contains FD90 and FDTL140 only: one window system and one compression-seal sliding door system.
FD90 window · FDTL140 sliding door set
This category contains two full-FRP systems. FD90 covers casement and tilt-and-turn window units; FDTL140 covers large sliding door sets with leaf compression at closing. Each project is checked against the cited certificate or catalogue configuration.
The grouping is based on profile construction and documented cold-region data. PD75 and PD95 use aluminium-composite sections and therefore remain in a separate category.
The category contains FD90 and FDTL140 only: one window system and one compression-seal sliding door system.
Both systems use pultruded glass-fibre composite profiles for the frame construction rather than aluminium shells connected by a composite insulating core.
FD90 adds PHI component certification at phB for the cool, temperate climate zone; both systems retain project-specific verification of glass, seals, hardware, joints and installation.
Cold-climate category
Choose by opening type and leaf size: FD90 for casement and tilt-and-turn windows, or FDTL140 for compression-seal sliding doors.

Cold-climate category
Full-FRP casement window system
A 90 mm full-FRP casement and tilt-and-turn system. PHI certificate 2491wi03 records class phB and Uw 0.78 W/(m²·K) for the certified configuration.

Cold-climate category
Full-FRP compression-seal sliding door set
A 140mm side-press sliding door for large winter openings: Grade 10 thermal insulation, 200kg leaf capacity and listed Uw of 1.02 W/(m²·K).
The comparison separates the supplied 2026 catalogue values from FD90's PHI certificate. Every thermal value remains tied to its identified configuration rather than serving as a universal project guarantee.
| Criterion | FD90 | FDTL140 |
|---|---|---|
| Product type | Casement / tilt-and-turn window | Compression-seal sliding door set |
| Construction | Full-FRP | Full-FRP |
| Nominal construction depth | 90 mm | 140 mm |
| Maximum sash / leaf load | 130 kg | 200 kg |
| Catalogue frame Uf | 0.85 W/(m²·K) | 0.90 W/(m²·K) |
| Listed whole-unit Uw | 0.85 W/(m²·K) | 1.02 W/(m²·K) |
| Catalogue thermal grade | Grade 10 | Grade 10 |
| PHI component certificate | 2491wi03 · phB · valid through 2026 | Not stated |
Category inclusion does not replace project qualification. Final thermal, structural, air, water, acoustic and durability claims must be confirmed for the ordered size, glazing, hardware, joints and installation method.